#Profibus_DP GSD_Revision = 3 Vendor_Name = "PROFIBUS-PA Profile" Model_Name = "Transmitter 8 AI (PhyL 0)" Revision = "3.0 (violet)" Ident_Number = 0x9707 Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "-" Software_Release = "-" Bitmap_Device = "pa_9707n" 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 500_supp = 1 1.5M_supp = 1 3M_supp = 1 6M_supp = 1 12M_supp = 1 MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_45.45 = 250 MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 6 Modular_Station = 1 Max_Module = 8 Max_Input_Len = 40 ; maximum Input Length Max_Output_Len = 0 ; maximum Output Length Max_Data_Len = 40 ; maximum In-Output Length Slave_Family = 12 Max_Diag_Data_Len = 14 Max_User_Prm_Data_Len = 3 Ext_User_Prm_Data_Const(0) = 0x00, 0x00, 0x00 ;----------- Description of extended DP features: --------------------- ; DPV1_Slave = 1 C2_Read_Write_supp = 1 C2_Max_Data_Len = 128 C2_Read_Write_required = 1 C2_Max_Count_Channels = 1 Max_Initiate_PDU_Length = 52 C2_Response_Timeout = 4000 DPV1_Data_Types = 1 ;---- Description of physical interface for asynchronous transmission: ---- ; RS485 Standard Copper can be selected without additional restrictions. ;----------- Description of device related diagnosis: --------------------- ; Unit_Diag_Bit(16) = "Error appears" Unit_Diag_Bit(17) = "Error disappears" Unit_Diag_Bit(24) = "Hardware failure electronics" Unit_Diag_Bit(25) = "Hardware failure mechanics" Unit_Diag_Bit(26) = "Motor temperature too high" Unit_Diag_Bit(27) = "Electronic temperature too high" Unit_Diag_Bit(28) = "Memory error" Unit_Diag_Bit(29) = "Measurement failure" Unit_Diag_Bit(30) = "Device not initialized" Unit_Diag_Bit(31) = "Device initialization failed" Unit_Diag_Bit(32) = "Zero point error" Unit_Diag_Bit(33) = "Power supply failed" Unit_Diag_Bit(34) = "Configuration invalid" Unit_Diag_Bit(35) = "Restart" Unit_Diag_Bit(36) = "Coldstart" Unit_Diag_Bit(37) = "Maintenance required" Unit_Diag_Bit(38) = "Characteristics invalid" Unit_Diag_Bit(39) = "Ident_Number violation" Unit_Diag_Bit(55) = "Extension Available" ;------------------------------------------------------------------------- ; ;Empty module Module = "Empty Module" 0x00 1 EndModule ; ;Modules for Analog Input Module = "Analog Input (AI)short" 0x94 2 EndModule ;Modules for Analog Input Module = "Analog Input (AI)long" 0x42,0x84,0x08,0x05 3 EndModule ;----------- Description of the module assignment: --------------------- ; SlotDefinition Slot(1) = "Analog Input" 2 1,2,3 Slot(2) = "Analog Input" 2 1,2,3 Slot(3) = "Analog Input" 2 1,2,3 Slot(4) = "Analog Input" 2 1,2,3 Slot(5) = "Analog Input" 2 1,2,3 Slot(6) = "Analog Input" 2 1,2,3 Slot(7) = "Analog Input" 2 1,2,3 Slot(8) = "Analog Input" 2 1,2,3 EndSlotDefinition